Eaton

Eaton 5PX G2 5PX3000IRT2UG2 UPS 3000 VA / 3000 W, RT2U, line-interactive

The Eaton 5PX3000IRT2UG2 (5PX 3000i RT2U G2) is a line-interactive UPS rated at 3000 VA / 3000 W. A power factor of 1.0 means the full rated capacity is available in watts, which makes it a fit for servers, storage systems and network racks that have to stay up through a power cut.

  • Capacity: 3000 VA / 3000 W
  • Power factor: 1.0 (3000 W / 3000 VA)
  • Topology: line-interactive
  • Model designation: 5PX 3000i RT2U G2 (rack/tower, 2U)
  • Series: Eaton 5PX G2
  • Weight: 31.7 kg

Description

3000 W with no power factor penalty

Many UPS units offer fewer watts than volt-amperes because their power factor is 0.6 to 0.9. Here both figures are 3000, so connected devices may draw up to 3000 W in total. That covers several servers together with a storage system and network switches. Leaving some headroom still extends battery runtime and keeps the UPS cooler.

Line-interactive for steadier mains power

A line-interactive UPS corrects minor mains voltage fluctuations without drawing on the battery and only switches to battery when power fails or the voltage leaves the permitted range. The batteries are not worn down by every small disturbance, and server room equipment receives more even power than it would straight from the grid.

RT2U: in a rack or as a tower

The RT2U in the model name marks the Eaton rack/tower version with a height of 2U, or two rack units. The UPS therefore fits a 19-inch server rack but can also stand upright on the floor. The manufacturer data does not say whether rails or a mounting kit are included, so check that before installation.

31.7 kg: a two-person install

According to the manufacturer the UPS weighs 31.7 kg, most of it in the batteries. In a server rack, mount it as low as possible to keep the centre of gravity down, and lift it with two people. Leave enough space in front of and behind the unit for airflow.

Who this UPS is for

Company server rooms where several servers and a storage system need time to shut down cleanly during an outage; IT administrators building a 19-inch network rack who want the UPS to take up only 2U; and offices where the network, phone system and point-of-sale system must not stop because of a power failure.

Specifications

BrandEaton
Capacity3000 W
Net weight31.70 kg
UPS topologyLine-Interactive
EAN743172104809

Questions & answers

How long does the UPS run on battery?

The manufacturer does not specify the runtime. It depends on the load: the lower the connected draw compared with 3000 W, the longer the batteries last.

Can it be mounted in a server rack?

Yes, RT2U denotes the rack/tower version with a height of 2U. Whether rails are included is not stated in the manufacturer data.

How much equipment can I connect?

Up to 3000 W in total, since the power factor is 1.0. The number and type of outputs are not listed in the manufacturer data, so check your device plugs beforehand.